工业内窥镜常见故障及应对措施

来源:http://www.jiangrenyiliao.cn/ 发布时间:2024-11-13 浏览量:0

  1.显示屏幕出现花屏、闪屏或黑屏等情况。 这种情况可能是由于内窥镜显示屏幕的连接线路不良或者内部电路出现问题,方法是检查连接线路是否...

  1. The display screen may appear as a splash screen, flashing screen, or black screen. This situation may be due to poor connection wiring of the endoscope display screen or internal circuit problems. The solution is to check if the connection wiring is

  2.内窥镜成像模糊或者颜色失真。 这种情况可能是由于内窥镜镜头污垢过多或者光源出现问题,可以尝试使用干净的软布清洁内窥镜镜头,如果清洁后...

  2. Endoscopic imaging is blurry or color distorted. This situation may be due to excessive dirt on the endoscope lens or problems with the light source. You can try using a clean soft cloth to clean the endoscope lens. If

  3.内窥镜无法伸缩或者弯曲。 这种情况可能是由于内窥镜的机械结构出现故障,需要将内窥镜送回售后服务中心或者的维修机构进行检修和维修。

  3. The endoscope cannot stretch or bend. This situation may be due to a malfunction in the mechanical structure of the endoscope, which requires the endoscope to be sent back to the after-sales service center or a professional repair organization for inspection and maintenance.

  4.内窥镜的电池不能正常充电或者电池寿命较短。 这种情况可能是由于内窥镜电池老化或者内窥镜充电线路不良导致的。 方法是更换新的电池或者检查充电线路是否正常。

  4. The battery of the endoscope cannot be charged normally or has a short battery life. This situation may be caused by aging of the endoscope battery or poor charging circuit of the endoscope. The solution is to replace the battery with a new one or check if the charging circuit is working properly.

  5.镜头无法对焦或者对焦困难。 这种情况可能是由于镜头结构出现问题,或者是镜头与内窥镜机身的连接处出现问题。 方法是检查连接处是否松...

  5. The lens cannot focus or has difficulty focusing. This situation may be due to problems with the lens structure or issues with the connection between the lens and the endoscope body. The solution is to check if the connection is loose

  6.光源不亮或者亮度不足。 这种情况可能是由于光源灯泡损坏,或者是光源电路出现问题。 方法是更换新的灯泡或者将内窥镜送回售后服务中心...

  6. The light source is not bright or the brightness is insufficient. This situation may be due to a damaged light bulb or a problem with the light source circuit. The solution is to replace the light bulb with a new one or send the endoscope back to the after-sales service center

  7.内窥镜机身变形或者损坏。 这种情况可能是由于内窥镜机身受到外力撞击或者过度挤压导致的。 方法是将内窥镜送回售后服务中心或者的维修机构进行检修和维修。

  7. The endoscope body is deformed or damaged. This situation may be caused by external impact or excessive compression on the endoscope body. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance.

20200408042119178

  8.内窥镜机身进水或者受潮。 这种情况可能是由于使用环境潮湿或者不当使用导致的。 方法是将内窥镜送回售后服务中心或者的维修机构进行检修和维修。

  8. The endoscope body is exposed to water or moisture. This situation may be caused by a humid environment or improper use. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance.

  9.内窥镜机身过热或者不工作。 这种情况可能是由于内窥镜电路出现问题或者内部散热不良导致的。 方法是将内窥镜送回售后服务中心或者的维修机构进行检修和维修

  9. The endoscope body is overheated or not working. This situation may be caused by problems with the endoscope circuit or poor internal heat dissipation. The solution is to send the endoscope back to the after-sales service center or a professional repair institution for inspection and maintenance

  我们专门为您提供内窥镜设备维修服务,想要了解更多的资讯内容,欢迎访问我们的网站:http://www.jiangrenyiliao.cn我们会有更多的内容等您查看。

  We specialize in providing maintenance services for endoscopic equipment. For more information, please visit our website: http://www.jiangrenyiliao.cn We will have more content waiting for you to review.

s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号