欢迎来到匠仁医疗设备有限公司网站!

更多 > 新闻资讯
公司新闻
行业知识
检测答疑
图标 首页 >> 新闻资讯 > 行业知识

行业知识

内窥镜设备表面出现破损怎么处理?

来源:http://www.jiangrenyiliao.cn/ 发布时间:2022-04-19 浏览量:0

  内窥镜设备在使用过程中会常常出现破损现象,这是有点不可避免的,所以就要做好找原因以及处理的准备,那么内窥镜设备表面出现破损怎么处理呢?下面来讲讲吧。
  Endoscope equipment in the use of the process will often appear damaged phenomenon, which is a little inevitable, so we should be ready to find the cause and treatment, then the surface of the endoscope equipment damage how to deal with it? So let's talk about it.
  从镜柜中取出悬挂式内窥镜时,需要一只手握住设备的操作部分,另一只手握住两个软管部分,以减少软管的锐角弯曲。共焦激光等内窥镜需要两个人相互配合才能取出和放置。内窥镜放置在镜架上时,操作部位和导光塞不应挤压软管,尤其是顶点部分。
  To remove the hanging endoscope from the cabinet, one hand holds the operating part of the device and the other hand holds the two hose parts to reduce the sharp Angle bending of the hose. Endoscopes such as confocal lasers require two people to work together to remove and place them. When the endoscope is placed on the frame, the operating part and light guide plug should not squeeze the hose, especially the apex part.
  镜架需要在一层放置内窥镜,另一侧放置其他尖锐器械。不要将内窥镜和锋利的器械混在一起。运输时,需要在运输工具下方放置较厚的巾,避免运输。在此过程中,内窥镜因碰撞而损坏。
  The frame requires an endoscope on one side and other sharp instruments on the other. Don't mix the endoscope with sharp instruments. During transportation, a thick treatment towel should be placed under the transportation vehicle to avoid transportation. In the process, the endoscope was damaged by collision.
  内窥镜悬挂后,插入部分需要保持静止和下垂,以防止其摆动。内窥镜主体与本科室插入部的接触部位应安装泡沫,可有效缓冲冲击。在进行手术前,医护人员需要耐心地向患者解释,尽量让患者保持放松。
  After the endoscope is suspended, the insertion part needs to remain still and droop to prevent it from swinging. Foam should be installed on the contact part between the main body of the endoscope and the insertion part of the undergraduate room to effectively cushion the impact. Before the operation, medical staff need to patiently explain to the patient, try to keep the patient relaxed.
  医护人员在对患者进行手术时,需要密切观察,了解口垫的固定状态。如果有紧急情况,需要提醒他们退出内窥镜。待患者病情稳定后,需要再次插入内窥镜。
  When performing surgery on patients, medical staff need to observe closely to understand the fixation state of the mouth pad. If there is an emergency, they need to be reminded to exit the endoscope. When the patient stabilizes, the endoscope needs to be inserted again.
  橡胶件长时间使用后,会出现相应的磨损。操作者在进出镜片时应尽量避免牙垫与橡胶接触。内窥镜不应放置在带有尖锐器械的罐中进行和清洁。
  There will be corresponding wear and tear after rubber parts are used for a long time. The operator should try to avoid contact between the tooth pad and rubber when entering or leaving the lens. Endoscopes should not be disinfected and cleaned in POTS with sharp instruments.
  为减少内窥镜设备维修的损坏,需遵循科室的操作原则,操作前需仔细检查附件的性能,如果遇到相应的阻力,需要先松开角度再扭动。使用内窥镜插入部分时,需要将其拉直,然后穿过以减少管道中的开口,损坏后不能再次使用。
  In order to reduce the damage of endoscopic equipment maintenance, it is necessary to follow the operating principles of the department. Before operation, the performance of the accessories should be carefully checked. If there is corresponding resistance, it is necessary to loosen the Angle and then twist. When using the endoscope insert section, it needs to be straightened and then passed through to reduce openings in the pipe, and cannot be used again if damaged.
  内窥镜设备表面出现破损怎么处理?以上就是使用时避免内窥镜出现破损的操作,如果您正在使用期间可以一看。想了解更多关于该设备的内容,可以来我们网站www.jiangrenyiliao.cn了解哦!
  Endoscope equipment surface damage how to deal with? The above is the operation to avoid the damage of the endoscope when using it, if you are using it can have a look. To learn more about the device, you can visit our website www.jiangrenyiliao.cn!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号