内窥镜与附件的损坏怎么进行有效处理

来源:http://www.jiangrenyiliao.cn/ 发布时间:2022-10-13 浏览量:0

如今内窥镜已广泛应用于各级医院,从硬式内窥镜到软式内窥镜,从纤维内窥镜到电子内窥镜,内窥镜越来越精细,也越来越昂贵,为使患者享受高质量的医疗服务,同时降低科室昂贵的维修费用,内窥镜故障的及时处理及日常维护保养显得尤为要。那么内窥镜与附件的损坏怎么进行有效处理?内窥镜设备维修人员为您讲解。
Nowadays, endoscopes have been widely used in hospitals at all levels. From hard endoscopes to soft endoscopes, from fiber endoscopes to electronic endoscopes, endoscopes are becoming more and more sophisticated and expensive. In order to enable patients to enjoy high-quality medical services, while reducing the expensive maintenance costs of departments, it is particularly important to timely handle the failures of endoscopes and daily maintenance. How to effectively deal with the damage of endoscope and accessories? The endoscope equipment maintenance personnel will explain to you.
1.内窥镜与附件损坏的类型:
1. Damage type of endoscope and accessories:
1).前没有洗净内窥镜----液使蛋白质凝固----内窥镜变色不光滑
1) The endoscope is not cleaned before disinfection ---- the disinfectant coagulates the protein ---- the endoscope discolors and is not smooth
2).使用未经验证的清洗方法或使用酸性水----不良的化学反应腐蚀内窥镜----内窥镜变色/脱皮
2) . Use unproven cleaning and disinfection methods or use acidic disinfection water ---- adverse chemical reaction corrodes the endoscope ---- endoscope discoloration/peeling
3).前没有洗净附件----液使蛋白质凝固,使活动部分卡住----附件操作异常并折断
3) The accessories were not cleaned before disinfection ---- the disinfectant coagulated the protein, causing the moving part to get stuck ---- the accessories were abnormal and broken
4).使用酸性水进行清洗----不良的化学反应腐蚀金属部分----附件生锈损坏
4) Use acidic disinfection water for cleaning and disinfection ---- adverse chemical reaction corrodes metal parts ---- accessories are rusted and damaged
5).使用未经验证的自动清洗机或使用不当----送水送气压力过大----内窥镜结构被压破,橡皮爆破
5) The use of an unverified automatic cleaning and disinfection machine or improper use ---- excessive water and air supply pressure ---- the endoscope structure is crushed and the rubber bursts
内窥镜设备维修
怎样避免内窥镜与附件的异常问题:
How to avoid the abnormal problems of endoscope and accessories:
1).内窥镜与附件前须洗净
1) Clean the endoscope and accessories before disinfection
2).对附件进行超声清洗
2) . Ultrasonic cleaning of accessories
3).避免使用非制定的清洗方法和酸性液
3) Avoid using non formulated cleaning and disinfection methods and acid disinfectant
4).避免使用非指定的自动清洗机
4) Avoid using non designated automatic cleaning disinfectors
5).请勿光顾非的修理站购买与维修
5) Do not patronize non repair stations for purchase and maintenance
长期不用的内窥镜应每1-2周检查1次,注意有无长霉、生锈,各牵引钢丝是否灵活,并定期吹干活检管道。镜面污物可用乙醚、乙醇或硅蜡擦净。更多相关注意事项就来我们网站http://www.jiangrenyiliao.cn咨询了解吧!
Endoscopes that have not been used for a long time should be checked every 1-2 weeks to see if there is mildew and rust, and if each traction wire is flexible, and the biopsy tubes should be dried regularly. The dirt on the mirror surface can be wiped with ether, ethanol or silicon wax. More relevant precautions come to our website http://www.jiangrenyiliao.cn Ask and understand!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号