内窥镜设备维修检查的基本方法是先外后内,先简单后复杂,先供电后电路,再检查电路中的插头和详细单元。还可根据数控系统的报警信息提示查看设备报警提示的相关部位,并可通过系统参数和检测功能查看设备的运行状态、负载、电流等状态,逐步减少故障范围,很后确定故障点。维修更换后,故障排除。
The basic method of maintenance and inspection of endoscope equipment is from outside to inside, from simple to complex, from power supply to circuit, and then check the plug and detailed unit in the circuit. It can also check the relevant parts of the equipment alarm prompt according to the alarm information prompt of the NC system, and check the operation state, load, current and other states of the equipment through the system parameters and detection function, so as to gradually reduce the fault range and determine the fault point later. Troubleshooting after maintenance and replacement.
我们在维修内窥镜时,一定要注意穿插感染的问题。例如:由于操作不规范,体液检测设备溅出的体液污染仪器表面,试剂污染仪器表面,激光设备过程中残留的表皮细胞、放化疗设备放射性粉尘的污染、环境污染、维修工具的污染等。
When we repair the endoscope, we must pay attention to the problem of interspersed infection. For example, due to non-standard operation, the body fluid splashed by the body fluid detection equipment pollutes the surface of the instrument, the reagent pollutes the surface of the instrument, the residual epidermal cells in the treatment process of the laser treatment equipment, the radioactive dust pollution of the radiotherapy and chemotherapy equipment, the environmental pollution, the pollution of the maintenance tools, etc.
维修此类设备时要注意,很好佩戴一次性手套,避免尿液、血液、激光后残留的表皮细胞、放射性粉尘等溅到皮肤上触碰。修复工作完成后,用肥皂和水彻底清洗裸露的皮肤,同时停止对所用工具的清洁和。
When repairing such equipment, pay attention to wearing disposable gloves to avoid splashing and touching the skin with urine, blood, residual epidermal cells after laser treatment and radioactive dust. After the repair work is completed, wash the exposed skin thoroughly with soap and water, and stop the cleaning and disinfection of the tools used.
此外内窥镜维修检测设备的包装强度检测包括包装材料的抗拉强度、复合膜的剥离强度、热封强度、撕裂强度、抗穿刺强度等指标。抗拉强度是指材料在断裂前承受的很大应力值。经测试,可有效处理因所选包装材料机械强度不足而因外力造成的包装破损、破损。
In addition, the packaging strength test of endoscope maintenance and testing equipment includes the tensile strength of packaging materials, peel strength of composite film, heat sealing strength, tear strength, puncture resistance and other indicators. Tensile strength refers to the large stress value borne by a material before fracture. After testing, it can effectively deal with the packaging damage and damage caused by external force due to the insufficient mechanical strength of the selected packaging materials.
内窥镜维修是检测复合膜中各层之间的结合强度。如果粘合强度过低,在封装应用中很容易出现层与层分离导致的渗漏等问题。热封强度是检测封口的强度。产品在储运过程中,一旦热封强度过低,就会造成热封开裂、内容物渗漏等问题。
Endoscope maintenance is to detect the bonding strength between layers in the composite membrane. If the bonding strength is too low, leakage caused by layer separation is easy to occur in packaging applications. Heat sealing strength is to test the strength of sealing. In the process of storage and transportation, once the heat seal strength is too low, it will cause heat seal cracking, content leakage and other problems.
Therefore, the daily management of endoscope to ensure its safety and effectiveness must be strictly controlled. For more information, please visit www.jiangrenyiliao.com Cn for consultation.