怎样确定内窥镜是否有问题?

来源:http://www.jiangrenyiliao.cn/ 发布时间:2020-05-08 浏览量:0

内窥镜能够有效的提高工作人员检查设备问题效率,可以检查部件内部的腐蚀、锈斑、铁屑异物、对接焊缝等质量缺陷等。那么它是怎样确定设备存在的问题呢?从下述几个方面可知设备出现了问题。
The endoscope can effectively improve the efficiency of the staff to check the equipment problems, and can check the quality defects such as corrosion, rust spots, iron scraps, foreign matters, butt welds and so on. So how does it identify the problem with the device? It can be seen from the following aspects that the equipment has problems.
1、裂纹
1. Crack
光束照射到被检测物体表面时,观察到黑色或者亮色线条,而且放大一定倍数,发现线条周围有不规则边缘时,可判定为裂纹。
When the light beam irradiates the surface of the detected object, black or bright lines are observed, and the magnification is a certain multiple. When irregular edges are found around the lines, it can be determined as cracks.
2、腐蚀
2. Corrosion
光束照射下,观察有块状、点状不光滑表面,在一定放大倍数下轻微凹凸不平为腐蚀。
Under the irradiation of light beam, it is observed that there are lumpy and spotty unsmooth surfaces. Under a certain magnification, slight unevenness is corrosion.
内窥镜设备维修
3、焊漏
3. Weld leakage
光束以合适角度照射时,观察到与熔化金属相连,无分界线的凸起时则为焊漏。
When the beam is irradiated at an appropriate angle, it is observed that it is connected with the molten metal, and when there is no bulge at the boundary, it is a welding leak.
4、起皮
4. Flaking
当光束平行照射时,发现在凸起部分背后有阴影;改变光束照射角度,则发现表面凸起部分与周围被检测物  有明显分界线,则可判定为起皮。
When the light beam is irradiated in parallel, it is found that there is shadow behind the convex part; when the light beam irradiation angle is changed, it is found that there is a clear boundary between the convex part of the surface and the surrounding detected object, it can be judged as peeling.
5、拉线和划痕
5. Stay wire and scratches
在光束照射下,如发现被测物表面存在较规则的连续性长线,判定为拉线。
Under the illumination of the beam, if it is found that there is a relatively regular continuous long line on the surface of the measured object, it is determined as a stay wire.
6、斑点
6. Speckles
在光束照射时,观察到与周围被检物色泽不同的光滑无凹凸表面可判定为斑点。
When the light beam irradiates, it is observed that the smooth non concave and convex surface with different color from the surrounding objects can be identified as spots.
关于内窥镜设备维修http://www.jiangrenyiliao.cn就先介绍到这里了,相信大家在实际的工作中会用到相关知识,如果您有这方面的需要,欢迎前来选购。
About the maintenance of endoscope equipment http://www.jiangrenyiliao.cn, I'm sure you will use the relevant knowledge in the actual work. If you have this need, welcome to purchase.
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号