1.手术时严禁大力弯折或碰撞;
During surgery, it is strictly prohibited to bend or collide vigorously;
2.使用辅助治设备时要保证在视野内操作,当窥镜配合激光汽化、高频电切、微波等光电技术进行手术时,应注意窥镜前端与点的距离,保证窥镜前端不被电击或烧灼;
2. When using auxiliary treatment equipment, it is necessary to ensure safe operation in the field of vision. When performing surgery with optoelectronic technologies such as laser vaporization, high-frequency electrocision, and microwave, attention should be paid to the distance between the front end of the endoscope and the treatment point to ensure that the front end of the endoscope is not electrocuted or burned;
3.术中调整视野角度时需保护好镜子本身,镜子与鞘管链接时必须对准位置并用卡锁固定,不易过猛;
3. Protect the mirror itself when adjusting the visual angle during the operation. When the mirror is connected with the sheath, it must be aligned to the position and fixed with a lock, which is not easy to be too violent;
4.建议单独存放避免与其它器械碰撞,必须轻取轻放以免碰撞镜子,镜子传像系统是玻璃柱体易碎;
4. It is recommended to store separately to avoid collision with other devices. It must be handled with care to avoid collision with the mirror. The mirror image transmission system is a glass column that is fragile;
5.建议手术前用温水浸泡,涂防雾油;
5. It is recommended to soak in warm water and apply antifogging oil before surgery;
6.在清洗和的时候,
内窥镜设备维修人员建议把镜子和别的手术器械分开,用塑料盆清洗;
When cleaning and disinfecting, the endoscope equipment maintenance personnel recommend that the mirror be separated from other surgical instruments and cleaned with a plastic basin;
7.前要把镜头清洗干净,否则异物在后积累在镜头上,以影响图像质量。当镜头上异物过多时,可用棉签涂一些镜子附带的清洁剂在镜面上,然后用清水清洗干净;
Clean the lens before disinfection, otherwise foreign matter will accumulate on the lens after disinfection, affecting image quality. When there are too many foreign matters on the lens, you can use a cotton swab to apply some of the cleaning agent attached to the mirror on the surface, and then clean it with clean water;
8.尽量不要频繁更换方法,这样对镜子的密封有好处;
8. Try not to frequently change the disinfection and sterilization methods, which is beneficial to the sealing of the mirror;
9.禁止用超声波清洗镜子,尽量不要用生理盐水清洗镜子,否则容易生锈迹;
9. It is prohibited to use ultrasound to clean the mirror, and try not to use physiological saline to clean the mirror, otherwise it will easily rust;
10.当高温高压完镜子后,一定要让镜子自然冷却,禁止用冷水冷却;
10. After high-temperature high-pressure disinfection of the mirror, it is necessary to allow the mirror to naturally cool, and it is prohibited to use cold water for cooling;
11.所以的镜子浸泡时间不能超过60分钟;
11. The immersion disinfection time of all mirrors should not exceed 60 minutes;
12.高温高压:建议尽量不要用高温高压,但在紧急时也可以进行高温高压。条件:建议控制高温高压时间及充分的自然冷却。
12. High temperature and high pressure disinfection: It is recommended not to use high temperature and high pressure disinfection as much as possible, but it can also be used in emergency situations. Conditions: It is recommended to control the sterilization time of high-temperature and high-pressure disinfection and sufficient natural cooling.
"The precautions for the use, cleaning, and disinfection of endoscope equipment have been explained. If you have any doubts or needs about this, please come to our website." http://www.jiangrenyiliao.cn Consult and understand!