医用内窥镜摄像机与监视器及光学内窥镜连接,可以帮助医生在手术中,清楚地查看病变位置,如椎间孔镜手术、关节镜手术、腹腔镜手术等等,在可视的情况下手术,大大地提高了手术成功率。
德国狼牌内窥镜设备维修厂家认为需要医生熟练的操作机器,并了解使用注意事项。
The connection of the medical endoscope camera with the monitor and the optical endoscope can help doctors clearly view the location of the lesions during surgery, such as intervertebral foraminal surgery, arthroscopic surgery, laparoscopic surgery, and so on. Operation under visual conditions greatly improves the success rate of the operation. The German Wolf brand endoscope equipment maintenance manufacturer thinks that doctors need to operate the machine skillfully and understand the precautions for use.
1)使用过程中导光束不要打折,以免对导光束有损坏,影响光的传输;
1) Do not discount the guide beam during use to avoid damage to the guide beam and influence the light transmission;
2)两次开关机之间需要间隔2-3秒;
2) The interval between two switching on and off is 2-3 seconds;
3)在通电情况下,不得搬动或摇动仪器,不得接插、拆装仪器的任何部件;
3) Under the condition of power on, the instrument shall not be moved or shaken, and any part of the instrument shall not be plugged or disassembled;
4)仪器应放置在清洁通风的室内使用,避免与化学物品及电磁、电场力强的电器放在一起;
4) The instrument shall be placed in a clean and ventilated room for use and shall not be placed with chemicals and electrical appliances with strong electromagnetic and electric field forces;
5)仪器表面由于静电作用,易吸收灰尘,擦拭时请先断开电源,用较为柔软的脱脂棉擦拭,避免表面划伤;
5) The surface of the instrument is easy to absorb dust due to static electricity. Please disconnect the power supply before wiping, and use a soft absorbent cotton to avoid scratches on the surface;
6)摄像机镜头表面有灰尘时,应用用脱脂棉和酒精擦拭;
6) When there is dust on the camera lens surface, it should be wiped with absorbent cotton and alcohol;
7)仪器应避免频繁的开关,否则易损坏。仪器不用时,应关闭电源,拔下外电源,盖好盖布;长期不用时,应擦拭干净,放在包装箱内,并定期打开通电运行一下(一般每隔一个月通电运行一次);
7) The instrument should avoid frequent switching, otherwise it is easy to be damaged. When the instrument is not in use, turn off the power supply, unplug the external power supply, and cover it with cloth; When it is not used for a long time, it should be wiped clean, put in the packaging box, and open it regularly for power on operation (generally once every other month);
8)内窥镜设备失去功能的故障时,禁止自行打开机壳,应与公司联系维修;
8) When the endoscope equipment fails to function, it is prohibited to open the casing by yourself, and the company should be contacted for maintenance;
9)仪器应用部分的表面温度超过41℃,暂停使用,使其冷却后再继续使用,以免烫伤;
9) If the surface temperature of the application part of the instrument exceeds 41 ℃, the instrument shall be suspended for further use after being cooled to avoid scalding;
10)更换照明LED光源时,一定要人士负责更换,禁止非人士操作;
10) When replacing the LED light source, professionals must be responsible for the replacement, and non professionals are not allowed to operate;
11)内窥镜使用前,要配上适宜的滤光片,以防止内窥镜光出射窗传输高能射光时,伤害眼睛;
11) Before the use of the endoscope, appropriate filters should be equipped to prevent eye injury when the endoscope light exit window transmits high-energy light;
12)设备的安装和调试只能由经过正规培训、具有操作资格的医技人员完成。
12) The installation and commissioning of the equipment can only be completed by medical technicians with formal training and operation qualification.
13)每次使用前须检查内窥镜和内窥镜附件部分是否引起危害:如表面粗糙、尖锐边缘或突出物;
13) Before each use, check whether the endoscope and its accessories cause safety hazards: such as rough surface, sharp edges or protrusions;
The above is about the precautions for using the medical endoscope camera. I hope it can help you better understand the machine. Correct operation can extend the service life of the machine. More relevant content will come to our website http://www.jiangrenyiliao.cn Consult!