来源:http://www.jiangrenyiliao.cn/ 发布时间:2023-02-21 浏览量:0

医疗用内窥镜设备定期保养一般由仪管员配合工程技术人员完成,它是一项不断循环进行的有组织有计划的维修措施,这有利于掌握仪器的运行规律,有利于出现故障后的查找:定期保养的内容和时间,不同仪器有不同的做法.一般可以分3个等级:
The regular maintenance of medical endoscope equipment is generally completed by the instrument controller in cooperation with the engineering technicians. It is an organized and planned maintenance measure that is carried out continuously and circularly, which is conducive to mastering the operation rules of the instrument and finding the fault after it occurs. The content and time of regular maintenance are different for different instruments. Generally, it can be divided into three levels:
(1)一保:一般可以一个月一个季度进行一次.主要内容除厂日常维护的工作外,可以拆开机壳,各处积尘,污垢、异物、紧固螺丝、添加润滑剂;检查务器件、元件有无磨损、变形、烧蚀、击穿、松动,受潮,老化、接地等情况;检测各组电源电压及纹波,检查高压部件运行和接触情况等;
(1) First maintenance: generally, it can be carried out once a month to once a quarter. In addition to the daily maintenance work of the factory, the main contents can be disassembled, dust, dirt, foreign matter, fastening screws, and lubricant can be added everywhere; Check the service devices and components for wear, deformation, ablation, breakdown, looseness, moisture, aging, grounding and other conditions; Check the power supply voltage and ripple of each group, and check the operation and contact of high-voltage components;
(2)二保:一般可以半年一年进行一次。主要内容除做好一保外,可以对整机控制台上的各个仪表及操作控制系统的灵敏度,精度进行测试校正和计量检定,更换高压发生器绝缘汕等到期的损耗品,对电路中各测试点的电压,波形进行系统检测和做拉偏试验;
(2) Secondary insurance: generally, it can be carried out once a year or half a year. In addition to the first guarantee, the main contents include testing, calibration and metrological verification of the sensitivity and accuracy of each instrument and operation control system on the console of the whole machine, replacement of expired loss products such as high-voltage generator insulation, systematic detection of the voltage and waveform of each test point in the circuit, and pull bias test;
(3)三保:一般可以2-4年进行一次:主要内容除做好二保外,要寸可以将整机进行全部拆卸子以清洗检修,超过使用期的元器件应尽量更换或修复,应对仪器进行较为彻底的调试,恢复其工作精度和性能,达到或超过新机的程度是完全有可能的。
(3) Three guarantees: generally, it can be carried out once every 2-4 years. In addition to the second guarantee, the whole machine can be fully disassembled for cleaning and maintenance. Components beyond the service life should be replaced or repaired as much as possible. The instrument should be thoroughly debugged to restore its working accuracy and performance. It is completely possible to reach or exceed the level of the new machine.
将擦干后的内镜置于多酶洗液中浸泡,时间按使用说明。使用后立即用流动水彻底清洗,并擦干。器械的轴节部、弯曲部、管腔内用软毛刷彻底刷洗,刷洗时注意避免划伤镜面。彻底清洗内镜各部件,管腔应当用高压水枪彻底冲洗,可拆卸部分必须拆开清洗,并用超声清洗器清洗5~10分钟。
Soak the dried endoscope in multi-enzyme lotion for the time specified in the instructions. Wash thoroughly with flowing water and wipe dry immediately after use. Thoroughly brush the shaft joint, bending part and lumen of the instrument with a soft brush, and pay attention to avoid scratching the mirror surface when brushing. Thoroughly clean all parts of the endoscope. The lumen should be thoroughly washed with a high-pressure water gun. The detachable part must be disassembled for cleaning and cleaned with an ultrasonic cleaner for 5 to 10 minutes.
在使用内窥镜之前,一定要认真阅读相关使用手册,在了解内窥镜的设计、制作工艺、性能等方面的情况的同时,也要注意相关使用操作说明和警告提示文字,除了要正确使用外,在清洗和存储保养等方面也要注意。主要从内窥镜的使用环境要求,手术前后的使用操作,以及术后的清洗方面来谈谈医用光学/光纤内窥镜清洗、维护等相关问题。有问题就来拨打我们的内窥镜维修电话http://www.jiangrenyiliao.cn吧!
Before using the endoscope, you must carefully read the relevant user manual. While understanding the design, manufacturing process, performance and other aspects of the endoscope, you should also pay attention to the relevant operating instructions and warning text. In addition to correct use, you should also pay attention to cleaning, storage and maintenance. Next, we will talk about the cleaning and maintenance of the medical optical/optical fiber endoscope from the aspects of the use environment requirements of the endoscope, the use and operation before and after the operation, and the cleaning after the operation. If you have any questions, please call our endoscope maintenance hotline http://www.jiangrenyiliao.cn Come on!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号