相关要求在每次重复使用前对内窥镜进行质量控制,此外,
内窥镜设备维修人员提醒您,须保存每一条内镜每次重复使用的记录,包括要有关于功能测试的文件,在硬式内镜再处理过程中有一些重要的步骤。
It is required to control the quality of the endoscope before each reuse. In addition, the maintenance personnel of the endoscope equipment remind you that you must keep the records of each reuse of the endoscope, including the documents about the function test. There are some important steps in the reprocessing process of the hard endoscope.
重要的步骤经常被遗忘,所造成的延误和混乱为致命,比如让患者在手术台上,焦急地等待着一条新内窥镜。在这些程序中,指定机构负责重复使用的器械,其中包括功能检测。
Important steps are often forgotten, and the resulting delay and confusion are fatal. For example, patients are waiting anxiously for a new endoscope on the operating table. In these procedures, the designated agency is responsible for the reuse of the device, including functional testing.
总之对内镜的整个再处理过程以及具体怎样使用它完全负责。如果出错太多,监查人员就会来查找问题所在。
In short, I am fully responsible for the whole reprocessing process of endoscope and how to use it. If there are too many errors, the supervisor will find the problem.
为了确保质量以及合规,根据法律要求,在整个再处理过程中要有义务做好记录。做好记录将在之后有特殊情况需要进行追溯时非常有帮助,不管是因为不当或是需要召回。
In order to ensure quality and compliance, it is necessary to keep records during the whole reprocessing process according to legal requirements. Keeping records will be very helpful when there are special circumstances that need to be traced later, whether it is due to improper disinfection or recall.
如果不能证明已经进行过检查和测试,出了问题就会被追责。因此,在清洗后,要检查与内镜相关的所有零部件是否受到腐蚀、表面是否受损、碎屑和污染。硬式内镜寿命通常是因为使用造成的老化和受损而终结。
If it cannot be proved that the inspection and test have been carried out, it will be held accountable for any problems. Therefore, after cleaning, all parts related to the endoscope should be checked for corrosion, surface damage, debris and contamination. The service life of rigid endoscope is usually terminated due to aging and damage caused by use.
不要忘了人们是不能随着时间的推移去发现内镜的逐渐变化的,但是机器可以。如果在检查过程中发现损坏就可以立刻将受损的内镜送去维修公司或及时进行更换。即使在清洗和过程中非常仔细,内镜中的光学玻璃表面和机械部件上仍有可能存有污渍,仍需要进行再次清洗和。
Don't forget that people can't discover the gradual changes of endoscopy over time, but machines can. If damage is found during the inspection, the damaged endoscope can be immediately sent to the maintenance company or replaced in time. Even if the cleaning and disinfection process is very careful, there may still be stains on the optical glass surface and mechanical parts in the endoscope, which still need to be cleaned and disinfected again.
That's all about the function detection when the endoscope is reused. If you have any doubts or questions about it, please come to our website http://www.jiangrenyiliao.cn consulting service