来源:http://www.jiangrenyiliao.cn/ 发布时间:2023-02-07 浏览量:0

关于医用内窥镜的故障检修您了解多少呢?为了让您更好更顺利的使用该设备,下面内窥镜维修公司为您讲解:
How much do you know about the troubleshooting of medical endoscope? In order to let you use the equipment better and more smoothly, the endoscope maintenance company will explain to you:
在组织管理方面:如划分技术专门的组,一专多能;计算仪器复杂系数,合理分担;分科室或仪器到人,包干负责;组织故障会诊;总工程师负责制等。
In terms of organization and management: such as dividing technical teams into specialized ones, with one specialty and multiple abilities; Calculate the instrument complexity coefficient and share it reasonably; Each department or instrument shall be responsible for the personnel; Organize fault consultation; Chief engineer responsibility system, etc.
在人才培养方面:如引进和培养相结合,逐步形成人才梯队,在职提高和外送培训相结合,基础理论深入和技术提高相结合等。
In terms of talent training: such as the combination of introduction and training, the gradual formation of talent echelon, the combination of on-the-job improvement and outward training, the combination of in-depth basic theory and professional technology improvement, etc.
内窥镜维修公司
在维修程序方面:先了解仪器故障起因,熟悉仪器的工作原理,然后运用自己掌握的基础理论知识针对仪器的电路图分析故障产生的可能部位,逐步检测排查,从中找出故障的真正部位,后修复或更换故障部件,并完成局部或整机调试。
In terms of maintenance procedures: first understand the cause of the instrument fault, be familiar with the working principle of the instrument, then use the basic theoretical knowledge that you have mastered to analyze the possible parts of the fault according to the circuit diagram of the instrument, and then gradually detect and troubleshoot, find out the real parts of the fault, then repair or replace the faulty parts, and complete the local or complete machine commissioning.
故障部位一般机械部分比电路部分多;强电部位比弱电部位多;高温部分比低温部分多;电源部分比主体部分多,传动部位比静止部位多,按插部位比固定部仿多,阻容器件比半导体器件多,模拟电路比数字电路多等客观规律,检测方法有敲击法、直观法、测量法、比较法,替换法、变温法,信号追踪法、信号输入法、前后合追法、负载分离法等实用方法。
Generally, the mechanical part is more than the circuit part; There are more strong current parts than weak current parts; The high temperature part is more than the low temperature part; The power part is more than the main part, the transmission part is more than the stationary part, the insertion part is more than the fixed part, the resistance and capacitance device is more than the semiconductor device, the analog circuit is more than the digital circuit, and other objective laws. The detection methods include knocking method, visual method, measurement method, comparison method, replacement method, temperature change method, signal tracking method, signal input method, front and back tracking method, load separation method and other practical methods.
维修方法:应遵循先询问,后诊断;先直观,后测查;先,后局部:先传动,后电路;先独立,后整机;先外围,后芯片;先控制,后数据;先定性,后定量等辩证关系的原则。更多的相关内容就来我们网站http://www.jiangrenyiliao.cn进行咨询吧!
Maintenance method: first inquire, then diagnose; First visual, then inspection; First comprehensive, then partial: first drive, then circuit; First independent, then complete machine; First peripheral, then chip; Control first, then data; The principle of dialectical relations such as first qualitative, then quantitative. Come to our website for more relevant content http://www.jiangrenyiliao.cn Consult!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号