内窥镜的使用严格具体表现在零部件中!

来源:http://www.jiangrenyiliao.cn/ 发布时间:2023-02-18 浏览量:0

在医院各科室中,医疗用内窥镜的使用非常严格,包括它的零部件使用,下面内窥镜设备维修公司为您讲解下相关内容。
In all departments of the hospital, the use of medical endoscope is very strict, including the use of its components. The endoscope equipment maintenance company will explain the relevant contents for you.
室内仪器定位放置:
Indoor instrument positioning:
手术间的电源插座应为屋顶悬挂式,避免因工作人员走动碰脱电源插座而使电源线受干扰,保证手术的顺利进行,同时也避免由于电压不稳而造成仪器损坏。
The power socket in the operating room should be roof-mounted to avoid the interference of the power cord caused by the staff moving and touching the power socket, so as to ensure the smooth operation and avoid the damage of the instrument due to the unstable voltage.
监视器:
Monitor:
一般监视器在安装时已经都是有相关技术人员进过测试并调整到了很好的显示状态,所以不建议使用者自行调试。如果监视器不显示,请检查插线板和电源线的连接,显示器开关是否处于打开状态、摄像系统是否处于打开状态、摄像系统的输出是否正确的连接到监视器的输入端口。
Generally, the monitor has been tested and adjusted to a good display state by relevant technical personnel during installation, so it is not recommended that users debug by themselves. If the monitor does not display, check the connection of the patch panel and the power cord, whether the display switch is on, whether the camera system is on, and whether the output of the camera system is correctly connected to the input port of the monitor.
颜色失真后可将摄像系统的光学接口对准颜色比较鲜明的物体或图片,通过监视器上的菜单进行对比度、饱和度、亮度的调节。避免强磁物体靠近监视器,定期作消磁保养,当磁化严重或消磁失效的时候,请联系厂家技术人员。
After color distortion, the optical interface of the camera system can be aimed at objects or pictures with bright colors, and the contrast, saturation and brightness can be adjusted through the menu on the monitor. Avoid strong magnetic objects close to the monitor, and perform degaussing maintenance regularly. In case of serious magnetization or degaussing failure, please contact the manufacturer's technical personnel.
摄像系统和光源:
Camera system and light source:
虽说很多医疗内窥镜声明光学接口是防水的,但光学接口和连接线不建议,可用套套上,每次使用时套,这样可以大大增加光学接口的使用寿命,如必须请用低温熏蒸的方法。
Although many medical endoscopes declare that the optical interface is waterproof, it is not recommended to disinfect the optical interface and the connecting line. It can be put on the germ-proof sleeve and sterilize the germ-proof sleeve every time it is used, which can greatly increase the service life of the optical interface. If it is necessary to disinfect, please use the method of low temperature fumigation.
内窥镜设备维修
插口不能强插拔,要对准十二点的位置进行直插、直拔轻拿轻放,定期作白平衡校准。防止光学接口接触液体,即使声称是防水的设备,所以不要将调焦头及连线浸泡,如不甚接触葡萄糖一类的液体请手术后立即用干布擦干净光学接口表面液体。防止卡口结晶运动不灵活,如果出现异常请不要勉强使用。
The socket cannot be forcefully inserted and pulled out. It should be directly inserted and pulled out at the position of 12 o'clock, handled gently, and regularly calibrated for white balance. Prevent the optical interface from contacting with liquid, even if it is claimed to be waterproof equipment, so do not immerse and disinfect the focusing head and wiring. If it does not contact with liquid such as glucose, please wipe the liquid on the surface of the optical interface with a dry cloth immediately after the operation. Prevent inflexible movement of bayonet crystallization. If there is any abnormality, please do not force to use it.
光缆不可用浸泡方式或高温高压方法,如需请用低温熏蒸或淡酒精擦拭表面的方法进行。使用者要细心记录光源灯泡的使用时间,临近使用寿命时准备备用灯泡。光源灯泡有使用寿命的限制,建议不使用时立即关闭光源。
The optical cable cannot be disinfected by immersion or high temperature and high pressure. If it needs to be disinfected, please use low temperature fumigation or light alcohol to wipe the surface. The user should carefully record the service time of the light source bulb and prepare the spare bulb when it is close to its service life. The light source bulb has a limited service life. It is recommended to turn off the light source immediately when it is not in use.
内窥镜对使用环境的要求为室内环境以暗室环境为主,避免强光直射,手术开始关闭日光灯,用无影灯照明,术前室内的温度保持在22℃~25℃、湿度50%左右、防酸、防碱、防蒸气。避免强电、电磁场的干扰。更多事项就来我们网站http://www.jiangrenyiliao.cn咨询了解!
The requirements for the use environment of the endoscope are that the indoor environment is mainly darkroom environment, avoiding direct sunlight, turning off the fluorescent lamp at the beginning of the operation, using shadowless lamp for lighting, and maintaining the indoor temperature at 22 ℃~25 ℃, humidity at about 50%, acid, alkali and vapor proof. Avoid interference of strong current and electromagnetic field. Come to our website for more matters http://www.jiangrenyiliao.cn Consult and understand!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号