欢迎来到匠仁医疗设备有限公司网站!

更多 > 新闻资讯
公司新闻
行业知识
检测答疑
图标 首页 >> 新闻资讯 > 公司新闻

公司新闻

椎间孔镜转镜破碎了怎么做修理?

来源:http://www.jiangrenyiliao.cn/ 发布时间:2023-04-22 浏览量:0

椎间孔镜转镜破碎是比较常见的问题,主要是因为手术过程中使用不当或者保养不当所造成的。以下是内窥镜维修公司给出的相关维修和预防的建议:
The breakage of intervertebral foramen mirror rotation is a common problem, mainly caused by improper use or maintenance during the surgical process. The following are the suggestions for maintenance and prevention provided by the endoscope maintenance company:
一般的修理流程如下:
The general repair process is as follows:
1.检查转镜损坏程度,确定是否需要更换。
1. Check the degree of damage to the rotating mirror to determine if it needs to be replaced.
2.如需要更换,在备件清单中选择合适的转镜备件。
If replacement is necessary, select the appropriate spare parts for the rotating mirror in the spare parts list.
3.拆卸老化或损坏的转镜,更换新的转镜,按照规定的程序安装回原位。
3. Disassemble the aged or damaged rotating mirror, replace it with a new one, and install it back in place according to the prescribed procedure.
4.完成更换后,进行的测试和校准,确保转镜的工作性能和手术效果与之前一致。
After completing the replacement, conduct comprehensive testing and calibration to ensure that the working performance and surgical effect of the rotating mirror are consistent with before.
5.根据修理结果进行记录和报告,保留相应的维护记录。
5. Record and report the repair results, and keep corresponding maintenance records.
内窥镜维修公司
注意:
be careful:
需要选择的医疗设备维修公司进行维修,不要自行拆卸和修复。
It is necessary to choose a professional medical equipment maintenance company for maintenance, and do not dismantle or repair it on your own.
维修前要对椎间孔镜进行的检测,确定转镜破碎是否是的问题。
Before maintenance, a comprehensive inspection of the intervertebral foramen mirror should be conducted to determine whether the breakage of the rotating mirror is the only problem.
维修公司需要更换破碎的转镜,并确保新的转镜符合原有的规格和要求。
The repair company needs to replace the broken rotating mirror and ensure that the new rotating mirror meets the original specifications and requirements.
维修后需要进行的测试和校准,确保转镜的工作性能和手术效果与之前一致。
After maintenance, comprehensive testing and calibration are required to ensure that the working performance and surgical effect of the rotating mirror are consistent with before.
在手术过程中,应该注意操作规范和技巧,并避免使用过大的力量和不合适的角度。手术后应该及时清洗和椎间孔镜,并妥善保管,避免碰撞和摔落等意外情况。定期进行检查和维护,包括对椎间孔镜和转镜进行的清洗、检测和校准等。使用的保养和维护工具,保证椎间孔镜和转镜的使用寿命和性能。更多相关事项就来我们网站http://www.jiangrenyiliao.cn咨询吧!
During the surgical process, attention should be paid to operational norms and techniques, and excessive force and inappropriate angles should be avoided. After surgery, the intervertebral foramen mirror should be cleaned and disinfected in a timely manner, and properly stored to avoid accidental situations such as collisions and falls. Regular inspection and maintenance, including comprehensive cleaning, testing, and calibration of the intervertebral foramen mirror and rotating mirror. Use professional maintenance and upkeep tools to ensure the service life and performance of the intervertebral foramen mirror and rotating mirror. For more related matters, come to our website http://www.jiangrenyiliao.cn Consult!
s
新闻资讯
联系我们
  • 公司公司:匠仁医疗设备有限公司
  • 匠仁医疗山东济南维修部
  • 联系人:樊经理
  • 电话:13153199508
  • 地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室
  • 匠仁医疗湖南长沙维修部
  • 联系人:李经理
  • 电话:13873135765
  • 地址:湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室
新闻资讯

樊经理:13153199508     李经理:13873135765

公司地址:山东省济南市槐荫区美里东路3000号德迈国际信息产业园6号楼101-2室  湖南省长沙市雨花区劳动东路820号恒大绿洲14栋2409室

     

鲁公网安备 37010402441281号