医疗器械
内窥镜设备维修主要关键点有什么呢?实际上医疗器械内窥镜设备维修检测设备包装强度检测包括包装资料抗拉强度、复合膜剥离强度、热封强度、撕裂强度、耐穿刺强度等指标。下面小编为您解答更多内容。
What are the main key points in the maintenance of medical instruments and endoscope equipment? In fact, the inspection of packaging strength of medical instrument endoscope equipment maintenance and inspection equipment includes tensile strength of packaging materials, peeling strength of composite film, heat sealing strength, tear strength, puncture resistance strength and other indicators. The following sections will answer more questions for you.
抗拉强度是指资料在拉断前接受大应力值,经过检测可以有效处理由于所选用的包装资料机械强度不够,而在遭到外力作用下产生的包装破损与断裂。
Tensile strength refers to the fact that the materials are subject to large stress values before being pulled off. After testing, it can effectively deal with the packaging damage and fracture caused by external forces due to insufficient mechanical strength of the selected packaging materials.
剥离强度也被称作复合强度,医疗器械内窥镜设备维修是检测复合膜中的层与层间的粘接强度,假如粘强渡过低,则易在包装运用中呈现层间别离而产生的泄露等问题。
Peel strength is also called composite strength. The maintenance of medical instrument endoscope equipment is to detect the adhesive strength between layers in the composite film. If the adhesive strength is too low, it is easy to present problems such as leakage caused by layer separation in packaging application.
热封强度是检测封口的强度,在产品的保管和运输过程中,一旦热封强度太低,则会招致热封处裂开、内容物走漏等问题。耐穿刺性能是对包装抗硬物刺穿才能停止评价的指标。
The heat sealing strength is used to detect the sealing strength. In the process of product storage and transportation, if the heat sealing strength is too low, it will lead to cracks at the heat seal, leakage of contents and other problems. Puncture resistance is an index to evaluate the puncture resistance of packaging to hard objects.
医疗器械内窥镜设备维修检查毛病的根本办法是先外后内,先简单后复杂,先电源后电路,再检查电路中的插头及详细单元。还能够依据数控系统的报警信息提示,检查设备报警提示的相关局部,能够经过系统的参数及检测功用,查看设备的运转状况,负载,电流等状态,逐渐减少毛病范围,终肯定毛病点,经过修复和改换之后,消弭毛病。
The basic way to repair and check the defects of medical instrument endoscope equipment is to go from outside to inside, from simple to complex, from power supply to circuit, and then check the plugs and detailed units in the circuit. It can also check the relevant parts of the equipment alarm prompt according to the alarm information prompt of the numerical control system. It can check the operating condition, load, current and other states of the equipment through the system parameters and detection functions, gradually reduce the range of faults, finally identify the fault points, and eliminate the faults after repair and replacement.
我们在医疗器械内窥镜设备维修的时分,要留意穿插感染的问题。例如:
We should pay attention to the problem of interpenetration infection when maintaining the medical instrument endoscope. For example:
体液检验设备因不标准操作溅出的体液对仪器外表的污染、试剂对仪器外表的污染、激光治疗类设备治疗时残留的外皮细胞对仪器外表的污染、放化疗设备放射性粉尘的污染、环境的污染、维修工具的污染等。
The body fluid splashed out by the body fluid testing equipment due to non-standard operation pollutes the appearance of the instrument, the reagent pollutes the appearance of the instrument, the residual skin cells during the treatment of laser therapy equipment pollute the appearance of the instrument, the radioactive dust pollution of radiochemotherapy equipment, the environmental pollution, and the pollution of maintenance tools.
在维修此类设备时,要留意,好戴一次性手套,避免溅出的尿液、血液、激光治疗后残留的外皮细胞、放射性粉尘等对皮肤的接触。维修工作完成后,要用肥皂水清洗暴露的皮肤,同时,对所运用的工具要停止清洗、消毒。更多相关事项就来我们网站
http://www.jiangrenyiliao.cn咨询吧!
During maintenance of such equipment, pay attention to wearing disposable gloves to avoid contact with skin by splashed urine, blood, residual skin cells after laser treatment, radioactive dust, etc. After the maintenance is completed, wash the exposed skin with soap and water, and stop cleaning and disinfection of the tools used. Come to our website for more information http://www , jiangrenyiliao, cn!